sql

ENVIROMUX-16DEL Enterprise Environment Monitoring System

Rp. 51.500.000
Update Terakhir
15 Nov 2024
Negara Asal
Canada
Pembelian Min
1 Unit
Kategori
NTI



ENVIROMUX – Environment Monitoring System

Environmental monitoring systems prevent hardware damage to server rooms, data centers and network closets with critical condition alerts and remote reboot capability.

Environmental threats in your server room can cause a lot more damage than hardware or software problems. Redundant hardware, backup tapes, UPS battery arrays, generators and other fault-tolerance measures can all be rendered useless if your server room overheats or floods. Don’t ignore environmental threats – remotely manage them with an ENVIROMUX® Server Environment Monitoring System or Intelligent Power Distribution Control Unit via TCP/IP Ethernet protocol over CAT5 through an RJ45 connector.

Monitor TemperatureThe most common environmental threat in any server room or wiring closet is heat. Detect critical rises or drops in temperature, and receive notifications when heating problems occur.

Monitor HumidityDetect abnormal humidity conditions. You define the humidity levels that are appropriate for each sensor’s environment.

Detect the Presence of WaterWhether it’s a tripped sprinkler system or a flash flood, a server room or wiring closet is just about the last place you want to see water. Receive notification as soon as water makes an appearance.

Monitor Physical SecurityMonitor “dry-contact” devices including motion sensors, door sensors, vibration sensors and smoke detectors.

Control PowerRemotely reboot and control power (on/off) to servers and network devices.

https://www.networktechinc.com/environment-monitor-16d.html

The E-16D monitors the parameters of many connected sensors used for detecting environmental conditions and sends out alerts to personnel when a sensor goes out of range of a configurable threshold. Alerts are sent via various communication channels such as: email, alarm beacon, siren, web page, network management (SNMP), voice phone calls, and SMS messages. Rapid changes in temperature and humidity, water leaks, power outages, human error, and invasive intrusions are the most common environmental threats faced by businesses. The E-16D reduces the unnecessary costs of expensive hardware replacement or unplanned downtime.

Server Komputer

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

enviromux-16d-bitama.pdf

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Minta Penawaran
Produk Siap di Pesan
Rp 0
1